Allied Telesis AT-S94 CLI (AT-8000S Series) User Manual
Page 203

PHY Diagnostics Commands
Page 202
7/e3
Copper
Temp – Internally measured transceiver temperature.
Voltage - Internally measured supply voltage.
Current – Measured TX bias current.
Output Power – Measured TX output power.
Input Power – Measured RX received power.
Tx Fault – Transmitter fault
LOS – Loss of signal
console> show fiber-ports optical-transceiver detailed
Power
Port
Temp
Voltage
Current
Output
Input
TX
LOS
[C]
[Volt]
[mA]
[mWatt]
[mWatt]
Fault
------
------
-------
-------
-------
-----
------
-----
7/e1
48
5.15
50
1.789
1.789
No
No
7/e2
43
5.15
10
1.789
1.789
No
No
7/e3
Copper
Temp – Internally measured transceiver temperature.
Voltage - Internally measured supply voltage.
Current – Measured TX bias current.
Output Power – Measured TX output power in milliWatts
Input Power – Measured RX received power milliWatts
Tx Fault – Transmitter fault
LOS – Loss of signal