Allied Telesis AT-S94 CLI (AT-8000S Series) User Manual

Page 203

Advertising
background image

PHY Diagnostics Commands

Page 202

7/e3

Copper

Temp – Internally measured transceiver temperature.

Voltage - Internally measured supply voltage.

Current – Measured TX bias current.

Output Power – Measured TX output power.

Input Power – Measured RX received power.

Tx Fault – Transmitter fault

LOS – Loss of signal

console> show fiber-ports optical-transceiver detailed

Power

Port

Temp

Voltage

Current

Output

Input

TX

LOS

[C]

[Volt]

[mA]

[mWatt]

[mWatt]

Fault

------

------

-------

-------

-------

-----

------

-----

7/e1

48

5.15

50

1.789

1.789

No

No

7/e2

43

5.15

10

1.789

1.789

No

No

7/e3

Copper

Temp – Internally measured transceiver temperature.

Voltage - Internally measured supply voltage.

Current – Measured TX bias current.

Output Power – Measured TX output power in milliWatts

Input Power – Measured RX received power milliWatts

Tx Fault – Transmitter fault

LOS – Loss of signal

Advertising