Power inline usage-threshold, Power inline traps enable – Allied Telesis AT-S94 CLI (AT-8000S Series) User Manual
Page 211

Power over Ethernet Commands
Page 210
power inline usage-threshold
The power inline usage-threshold Global Configuration mode command configures the threshold for initiating
inline power usage alarms. Use the no form of this command to return to the default configuration.
Syntax
power inline usage-threshold percentage [unit-number]
no power inline usage-threshold
Parameters
•
percentage — Specifies the threshold as a percentage to compare measured power. (Range: 1-99)
•
unit-number — Specifies the current number of the unit. (Range: 1-6)
Default Configuration
The default threshold is 95 percent.
Command Mode
Global Configuration mode
User Guidelines
There are no user guidelines for this command.
Example
The following example configures the power usage threshold for which alarms are sent to 80%.
power inline traps enable
The power inline traps enable Global Configuration mode command enables inline power traps. Use the no form
of this command to disable inline power traps.
Syntax
power inline traps enable [unit-number]
no power inline traps enable
Parameters
•
unit-number — Specifies the current number of the unit. (Range: 1-6)
Default Configuration
Inline power traps are disabled.
Command Mode
Global Configuration mode
console(config)# power inline usage-threshold 80