C13016 | active multicast ip address, C13017 | ethernet config control, C13016 – Lenze E94AYCEO User Manual

Page 93: C13016/1, 13 parameter reference

Advertising
background image

13

Parameter reference

13.2

Parameters of the communication module for slot MXI1

93

Lenze · E94AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 12/2013 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C13016

C13017

Parameter | Name:

C13016 | Active Multicast IP Address

Data type: UNSIGNED_8

Index: 11559 = 0x2D27

Display of the active multicast IP address
Display range

(min. value | unit | max. value)

0

255

Subcodes

Info

C13016/1

Multicast IP address (most significant byte)

C13016/2

Multicast IP address

C13016/3

Multicast IP address

C13016/4

Multicast IP address (least significant byte)

Read access  Write access  CINH  PLC STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13017 | Ethernet Config Control

Data type: UNSIGNED_16

Index: 11558 = 0x2D26

Setting of the baud rate for the Ethernet connections

• Depending on the configuration of the Ethernet port of the device to be connected, we recommend the use of a

cross-over cable.

EtherNet/IP connection ( 28)

• After changing the setting, carry out a "Type 0 Reset" for the

Identity Object (1 / 0x01) ( 121)

of the node or

switch off and on the voltage supply of the communication module.

Selection list

0 Auto-Negotiation
1 Reserved
2 Reserved
3 Reserved
4 Reserved
5 10 Mbps/Half Duplex
6 10 Mbps/Full Duplex
7 100 Mbps/Half Duplex
8 100 Mbps/Full Duplex
9 Reserved

10 Reserved
11 Reserved
12 Reserved

Subcodes

Lenze setting

Info

C13017/1

0: Auto-Negotiation

Ethernet setting port X233

C13017/2

0: Auto-Negotiation

Ethernet setting port X234

Read access  Write access  CINH  PLC STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Advertising