Lenze · E94AYCER communication module (PROFINET®) · Communication Manual · DMS 9.0 EN · 12/2013 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.2

Protocol data

4.3

Communication time

The communication time is the time between the start of a request and the arrival of the

corresponding response.
The communication times in an PROFINET network depend on the ...

• processing time in the inverter;
• telegram runtime (baud rate / telegram length);
• nesting depth of the network.

processing time within the inverter

The times specified apply if the TCP/IP channel of the communication module is not used

(»Engineer« communication, chapter

Setting the IP configuration

( 37)

).

There are no interdependencies between parameter data and process data.

Range

Values

Process data words (PCD)

Maximally 32 process data words (max. 64 bytes)

PROFIsafe message

4 words (8 bytes)

Acyclic parameter data channel

Limited by the PROFINET frame size

Data

Processing time

Process data (IO data)

10 ms

+ 0 ... 1 ms

+ 1 ... x ms

Lenze standard update cycle (can be changed in the Rockwell

engineering tool)

Processing time in the module

Runtime of the application task of the technology

application used (tolerance)

Parameter data

Approx. 30 ms + a tolerance of 20 ms (typically)

Some codes may require a longer processing time (see reference manual/

»Engineer« online help for the Servo Drive 9400).