14 parameter reference, C00615 | resp. to imp. device conf, C00636 | resp. to new module in mxi1 – Lenze E94AYCER User Manual

Page 89: Parameter reference, Communication

Advertising
background image

Lenze · E94AYCER communication module (PROFINET®) · Communication Manual · DMS 9.0 EN · 12/2013 · TD17

89

14

Parameter reference

14.1

Parameters of the standard device that are relevant to communication

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

14

Parameter reference

This chapter supplements the parameter list and the table of attributes contained in the reference

manual and in the »Engineer« online help for the Servo Drive 9400 with the parameters of the

E94AYCER (PROFINET) communication module.

14.1

Parameters of the standard device that are relevant to communication

In this chapter communication-relevant parameters of the Servo Drive 9400 are listed in

numerically ascending order.

C00615

C00636

Reference manual/»Engineer« online help for Servo Drive 9400
Here you will find general information on parameters.

Parameter | Name:

C00615 | Resp. to imp. device conf.

Data type: UNSIGNED_32

Index: 23960 = 5D98

Response to impermissible device configuration
Selection list

1 Fault
3 Quick stop by trouble
4 Warning Locked
6 Information
0 No response

Subcodes

Lenze setting

Info

C00615/1

0: No Response

Reserved

C00615/2

1: No response

Resp. to imp. module in MXI1

C00615/3

1: No response

Resp. to imp. module in MXI2

C00615/4

0: No Response

Reserved

C00615/5

0: No Response

Reserved

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C00636 | Resp. to new module in MXI1

Data type: UNSIGNED_32

Index: 23939 = 5D83

Response for the case where a new module has been plugged into slot 1 of the standard device.
Selection list

(Lenze setting printed in bold)

1 Fault
6 Information
5 Warning
4 Warning Locked
3 Quick stop by trouble
0 No response

Read access  Write access  CINH  PLC-STOP  No transfer

Advertising