Configuring process input data

The assignment of the bit status information or actual values of the controller to the max.
4 process input data words (PIW) of the master can be configured freely:

ƒ

In order to access DRIVECOM−compliant status information, assign the DRIVECOM
status word to a PIW (C1511/x = 18).

ƒ

The FIF status word 1 is mapped to the DRIVECOM status word.

Configuration of the process input data

Code

C1510

Name

Configuring process input data

Index

0x5A19 (23065)

Subcode

Lenze

Access

Data type

1

PIW1

18

DRIVECOM status word (DRIVECOM−STAT)

rw

FIX32

2

PIW2

3

Output frequency with slip (MCTRL1−NOUT+SLIP)

rw

FIX32

3

PIW3

4

Output frequency without slip (MCTRL1−NOUT)

rw

FIX32

4

PIW4

5

Apparent motor current (MCTRL1−IMOT)

rw

FIX32