Codetabelle, Diagnostics – Lenze E82ZAFIC010 User Manual

Page 65

Advertising
background image

Codetabelle

Diagnostics

10

l

65

EDS82ZAFIC EN 2.0

C1523:
Display of all process data words from the standard device

Code

C1523

Name

Display of all process data words from the standard
device

Index

0x5A0C (23052)

Subcode

Lenze

Values

Access

Data type

1 ... 16

g

0

[1]

65535 r

U16

o Parameter set transfer

Display of the process data words 1 ... 16 that are transferred from the standard device to
the function/communication module:

Subcode

Process data word

1 FIF status word 1 (FIF−STAT1)

2 FIF status word 2 (FIF−STAT2)

3 Output frequency with slip (MCTRL1−NOUT+SLIP)

4 Output frequency without slip (MCTRL1−NOUT)

5 Apparent motor current (MCTRL1−IMOT)

6 Actual process controller value (PCTRL1−ACT)

7 Process controller setpoint (PCTRL1−SET)

8 Process controller output (PCTRL1−OUT)

9 Device utilisation (MCTRL1−MOUT)

10 DC−bus voltage (MCTRL1−DCVOLT)

11 Ramp function generator input (NSET1−RFG1−IN)

12 Ramp function generator output (NSET1−NOUT)

13 FIF−OUT.W1

14 FIF−OUT.W2

15 FIF−OUT.W3

16 FIF−OUT.W4

C1525:
Display of the current DIP switch positions (S2 ... S4)

Code

C1525

Name

Display of the current DIP switch positions (S2 ... S4)

Index

0x5A0A (23050)

Subcode

Lenze

Values

Access

Data type

g

0

[1]

7 r

FIX32

o Parameter set transfer

This code shows the current settings of the DIP switches S2 ... S4. These switches serve to
set the number of process and parameter data words (

30).

DIP switch

Value

S2

1

S3

2

S4

4

Advertising