3 examples, 1 connection of proximity switch, 1 features – Pilz PNOZ s30 24-240VACDC 2 n/o 2 n/c User Manual
Page 83: 2 configuration overview, Examples, Connection of proximity switch
Advertising
![background image](/manuals/647243/83/background.png)
Supplementary data
Operating Manual PNOZ s30
1001715-EN-13
83
Examples
Connection of proximity switch
Features
PNOZ s30
}
Standstill monitoring for enabling the safety gate via Rel. 1:
Standstill is detected at <= 2 Hz, the output Rel. 1 switches on and the safety gate can
be released with the pushbutton S3.
}
Monitoring for overspeed via Rel. 2:
Overspeed is detected at >= 500 Hz and the output Rel. 2 switches off.
}
Feedback loop monitoring for Rel.1 via feedback loop input Y1,
Feedback loop monitoring for Rel.2 via feedback loop input Y2
}
Automatic reset
Encoder
The measured values are detected by two proximity switches (pnp).
PNOZ s4
}
Safety gate monitoring