Measurement of Pitch

The single pitch of connectors pins or IC pins is measured by the LS-7000 Series. Further-
more, multiple pitch of pins is measured with the program function or RS-232C interface
used.

Set Values

Set item

Calibration

Tolerance setting

Area setting

Output

setting

AREA

Operation

Averaging

Measuring mode

Offset

Set value

AREA 1

Head 1

SEG

(002-P, 004-P)

Make settings if required.

A1: 1.0

A2: OFF

Select the value according to the line speed

Sample hold 1/2

No settings are required

Head 1

SEG

(004-P, 006-P)

A1: OFF

A2: 1.0

Select the value according to the line speed

Sample hold 1/2

No settings are required

Set the upper and lower limit values.

AREA 2

OUT 1

OUT 2

Reference

RS-232C (Page 7-1)
Area Settings (Page 4-7)
Calibration Settings (Page 4-20)
Output Settings (Page 4-28)
Tolerance Settings (Page 4-50)

The center pitches of the two portions
are measured at a time.