Measurement of pitch – KEYENCE LS-7000 User Manual
Page 44
2-8
2
Chapter 2 Easy Setting Guide
Measurement of Pitch
The single pitch of connectors pins or IC pins is measured by the LS-7000 Series. Further-
more, multiple pitch of pins is measured with the program function or RS-232C interface
used.
■ Set Values
Set item
Calibration
Tolerance setting
Area setting
Output
setting
AREA
Operation
Averaging
Measuring mode
Offset
Set value
AREA 1
Head 1
SEG
(002-P, 004-P)
Make settings if required.
A1: 1.0
A2: OFF
Select the value according to the line speed
Sample hold 1/2
No settings are required
Head 1
SEG
(004-P, 006-P)
A1: OFF
A2: 1.0
Select the value according to the line speed
Sample hold 1/2
No settings are required
Set the upper and lower limit values.
AREA 2
OUT 1
OUT 2
■ Reference
RS-232C (Page 7-1)
Area Settings (Page 4-7)
Calibration Settings (Page 4-20)
Output Settings (Page 4-28)
Tolerance Settings (Page 4-50)
The center pitches of the two portions
are measured at a time.