KEYENCE LS-7000 User Manual
Page 86
4-34
Chapter 4 Function Settings
4
Application Example of Measuring modes
Select the measurement mode according to the type of target and measuring condition.
The following applications are typical examples of measurement in a variety of Measur-
ing modes.
Application
Applicable RUN mode
Normal
Continuous measurement of
wire, tube, or fiber
Peak Hold
Auto Peak Hold
Measurement of maximum
value within specified period
Bottom Hold
Auto Bottom Hold
Measurement of minimum
value within specified period
Peak-to-peak Hold
Auto Peak-to-peak Hold
Measurement of maximum-to-
minimum value within specified
period
Average Hold
Measurement of average
values within specified period
Peak Hold
Auto Peak Hold
Measurement of maximum
value per rotation
Bottom Hold
Auto Bottom Hold
Measurement of minimum
value per rotation
Peak-to-peak Hold
Auto Peak-to-peak Hold
Measurement of maximum-to-
minimum fluctuation or
eccentricity per rotation
Average Hold
Measurement of average value
per rotation
Sample Hold 1
Sample Hold 2
Self-timing Hold
Single workpiece
measurement