EVCO EVB1256N9D User Manual

Page 51

Advertising
background image

EVCO S.p.A.

EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134

page 51 of 92

d8

0

4

- - - -

0

0

0

0

0

0

0

0

defrosting activation methods

0

=

AT INTERVALS - defrosting will be activated once

the device has altogether been running for time

d0

1

=

AT INTERVALS - FOR COMPRESSOR SWITCH-ON -

defrosting will be activated once the compressor

has altogether been switched on for time d0

2

=

AT INTERVALS - FOR EVAPORATOR TEMPERATURE

- defrosting will be activated when the evaporator

temperature has remained below the temperature

d9 for a total time of d0 (17)

3

=

ADAPTABLE - defrosting will be activated at

intervals, whose duration will each time depend

on the duration of compressor switch-ons and the

evaporator temperature; see also d18, d19, d20

and d22 (17)

4

=

IN REAL TIME - defrosting will be activated at the

times established in parameters Hd1... Hd6 (not

visible in models EVB1204, EVB1206, EVB1226

and EVB1246)

d9

-99

99.0

°C/°F

(1)

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

evaporator temperature is higher than that at which the

defrost interval counter is suspended (only if d8 = 2)

d11

0

1

- - - -

0

0

0

0

0

0

0

0

defrosting alarm switches off once maximum time limit

has been reached (code “dFd”; only if P3 = 1 and in

absence of an evaporator temperature probe (code “Pr2”)

1

=

YES