EVCO EVB1256N9D User Manual

Page 55

Advertising
background image

EVCO S.p.A.

EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134

page 55 of 92

A7

0

240

min

15

15

15

15

15

15

15

15

temperature alarm delay (code “AL” and code “AH”)

A8

0

240

min

15

15

15

15

15

15

15

15

delay in maximum temperature alarm (code “AH”) from

the conclusion of evaporator fan standstill (21)

A9

0

240

min

15

15

15

15

15

15

15

15

delay in maximum temperature alarm (code “AH”)

following the deactivation of the door micro switch input

(22)

A10

0

240

min

1

not

avail.

1

not

avail.

1

not

avail.

1

duration of a power cut such to cause the power cut alarm

to be memorised (code “PF”)

A11

0.1 (5)

15.0

°C/°F

(1)

2.0

2.0

2.0

2.0

2.0

2.0

2.0

2.0

differential of parameters A1 and A4

A12

0

2

- - - -

not

avail.

1

not

avail.

1

not

avail.

1

not

avail.

1

type of power supply cut-off alarm signal (code “PF”)

0

=

alarm will be signalled by the “HACCP” LED

1

=

alarm will be signalled by the “PF” code, the

buzzer and the “HACCP” LED

2

=

alarm will be signalled by the “PF

code, buzzer

(as long as cut-off duration exceeds time A10)

and by the “HACCP” LED