EVCO EVB1256N9D User Manual

Page 60

Advertising
background image

EVCO S.p.A.

EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134

page 60 of 92

i1

0

1

- - - -

0

0

0

0

0

0

0

0

type of door micro switch input contact

0

=

normally open (active input with closed contact)

1

=

normally closed (active input with open contact)

i2

-1

120

min

30

30

30

30

30

30

30

30

delay in signalling of door micro switch input alarm (code

id”)

-1

=

the alarm will not be signalled

i3

-1

120

min

15

15

15

15

15

15

15

15

maximum duration of the effect caused by the activation

of the door micro switch input on the compressor and the

evaporator

i4

0

1

- - - -

0

0

0

0

0

0

0

0

storage of door micro switch input alarm (code “id”) (32)

1

=

YES