A0xx05 Keypad Selections “xx” represents the area number.

WARNING: These Access Control features are only available with the addition of the “Feature Expansion Board”.

(left to right on keypad screen) Example:



Default Name

Selections

Description

0

Anti-Pass Back Auto
Reset

0:don’t autoreset
1:10Mins, 2:20Mins,
3:30Mins, 4:1Hr,
5:4Hrs, 6:8Hrs
7:12Hrs

Timed lock out condition for a card holder resets after
they failed to read their card to enter/leave previously.

(no)

Strict Anti-Pass Back
Entry/Exit Enforcement

(yes)

(no)

Whether users will be able to enter other areas without
having been recorded as leaving the present one.

(no)

No Anti-Pass Back
Outside Check

(yes)

(no)

Allows users who didn't 'badge' out of the facility to re-
enter through an APB controlled area. With this
setting, cards being used to enter from 'outside' of the
facility will not be checked for being previously used to
exit (although other APB rules will still apply). Note:
Cannot be their last known area (to allow this, set APB
auto-reset to e.g. 8 hrs).

(no)

Lockout all Users on
Invalid Card

(yes)

(no)

(yes) Lockout all users, even when access is granted (in

case of global lockout)

(no)

Generate Tones on
Invalid Card

(yes)

(no)

Keypads sound when an invalid card is detected.

A0xx06

Area User Counters

Keypad Selections “xx” represents the area number.

WARNING: These Access Control features are only available with the addition of the “Feature Expansion Board”.

(left to right on keypad screen)

Default Name

Selections

Description

00000

Maximum Area Counter

0 – 16383

Maximum number of users
counted in an area before an
“area full” condition occurs.

00

Minimum Area Counter

0 – 15

Minimum number of users
counted in an area before an
“area empty” condition occurs.

0

Reset Before Schedule
in Effect

1 – 7
0=Not used,
1=1hr prior...
2=2hr prior..
3=3hr prior.
4=4hr prior.
5=5hr prior.
6=6hr prior.
7=7 hrs prior to In Schedule Time

User count resets to “0” at the
time selected before the area’s
schedule starts.
NOTE: there must be a schedule
assigned to the area.

0

“Users in Area” Counts
Increase or Decrease

(Count Mode)

0 = “Normal”: the user count for the area
being entered will increase and the area
being exited will be decreased.
1 = “User Area Based”: the user count for
the area being entered will increase and the
last known area the user was in will be
decreased.

2= Blind mode

Selection “1” NOTE: If “Timed
Anti-pass Back” is selected and
the timer expires, information
about the area the user was last
in will not exist. The user count
for the area they just came from
will be decreased.

(no)

Reset On Disarm To
Off

(yes)

(no)

User count resets to “0” when
the area is turned off.

(no)

Reset On Arm To On

(yes)

(no)

User count resets to “0” when
the area is turned on.

0

·



···········

Save A001