Output Selections Table
WARNING: Access Control related outputs can only be used
with the addition of the “Feature Expansion Board”.
Program Section (“q”)
“S”ystem
Section Range (“nnn”)
000 – 000
Code
“cc”
Description
00
Fallback sonalert (at control panel) if
Module Bus fails. Provides 1 sec. Output
every 8 sec. And activates if there is no
operational keypad in an area with
programmed keypads.
01 Not
Used
02
When system is FULLY ON
03
PARTIALLY ON. One or more areas
ON.
04
When system is FULLY OFF
05
When system is IN ALARM - resets
when point(s) restore
(includes pseudos & tampers)
06
Follows ALARM (BURG / EMERG) &
FIRE siren steady.
07
Follows ALARM siren - steady for BURG
/ EMERG. Keypad tone & siren is 1 sec
on/off for FIRE.
For UL: When using this output type,
fire siren is ½ sec on/off three times, 1.5
sec pause, and repeats. Keypad tone is
1 sec on/off.
08
Follows ALARM siren - steady for BURG
/ EMERG and provides 2 sec on/off for
FIRE
09
Digital PHONE LINE trouble (follows
report delay or line failure)
10
System WAS IN ALARM. This is only for
input points in alarm e.g. NOT for
system trouble (clears when alarmed
areas are turned off then back on again)
11
When there is a point BYPASSED
somewhere in the system
12
When any ‘FIRE’ point is in alarm
13
When any ‘HOLD UP’ point is in alarm
14
When any ‘Aux Alert' point is in alarm
15
When any ‘VAULT / SAFE’ type point is
in alarm
16
When any ‘'Burglary' point is in alarm.
Delayed burglary for European
Version.
17
When any ‘Supervisory' point is in alarm.
18
When any 'Pseudo' is in alarm
19
Pseudo 1 – System Trouble / All type
tamper for European Version.
20
Pseudo 2 – Battery Trouble
21
Pseudo 3 – AC (Mains) Trouble
22
Pseudo 4 – Phone Trouble
23
Pseudo 5 – Report Delay
24
Pseudo 6 – Time Lost
25
Pseudo 7 – Time Change
26
Pseudo 8 – Program Change
27
Pseudo 9 – Program Error
28
Pseudo 10 – Fuse Failure
29
Pseudo 11 – Module Trouble
30
Pseudo 12 – Module Battery Low
31
Pseudo 13 – Module Program Edit
32
Pseudo 14 – Module Program Error
33
Pseudo 15 – Misc. Trouble
34
Pseudo 16 – SIP Trouble
35 Duress
Pin
36 Doors
Unlocked.
37
Doors Locked Out
38 Doors
Held
Open
39 Doors
Forced
40
Doors Tamper (door contact condition:
no EOL resistor etc.)
41 Doors
Open
42 Doors
Secure
43
Doors Sensor Trouble (magnetic bond
sensor not ok)
44
Global Invalid PIN and / orCard lockout.
45
Host (Director) computer is On-Line.
46
Host (Director ) computer is Off-Line.
Response time for IP, external modem,
direct connection is 2 min. Bell 103 is 1
min.
47 SIP
On-Line.
48
SIP Off-Line. Response time is 3
minutes.
49
Any point in tamper.
50
Any point in Alarm.
51
Any area is Force Arming
52
Any area Failed to Close
53
Phone Line Failure
54
Local AC (mains) failure.
55
System Tamper – European Version.
56
System Fault – European Version.
57
System WAS IN ALARM. This is only for
input points in alarm e.g. NOT for
system trouble (clears when alarmed
areas are turned off)
58
Bypass is in effect in any armed area.
European
Version (System)
59 Fire
60 Personal
Attack
61 Unconfirmed
Alarm
62
Area Set / Unset
63
Freezer / Fire Fault
64
Bypass in Effect
65 Confirmed
Alarm
66 Siren
67 Confirmed
Alarm
(Strobe)
System Special Outputs. Section Range: 001 – 001. See
examples 8 & 9 in Output Examples. NOTE: Only
configurable through the Director Software.
00
1 sec on, 1 sec off
01
2 seconds on every minute
02
10 seconds on every minute