Save d001, 0 mm, Save h001 – Interlogix Monitor XL Advanced Installation Guide User Manual
Page 54
48
Monitor xL™ Advanced Installation Guide
21-3602E rev1.5
Program Section: H001 (Holidays)
H00100 Keypad Selections
(left to right on keypad screen) Example:
Default Name
Selections
Description
00
Month
Up to 2 digits:
01 – 12
13 = Reserved (for future e.g. Easter, Yom Kippur, etc)
00
Day
Up to 2 digits:
01 - 31: Day of month
32 - 38: 1st Sun–Sat of month
39 - 45: Last Sun–Sat of month
46 – 52: 2
nd
Sun–Sat of month
53 – 59: 2
nd
last Sun–Sat of month
60 – 66: 3
rd
Sun–Sat of month
67 – 73: 3
rd
last Sun–Sat of month
0
Type One
digit
0: No access holiday
1: Holiday Type One
2: Holiday Type Two
3: Holiday Type Three
H001:0 always programs the seasonal spring-forward (daylight savings time) date.
H002:0 always programs the seasonal fall-back (standard time) date.
Program Section: D001 (Schedules)
D00100 Keypad Selections
(left to right on keypad screen) Example:
Default Name
Selections
Description
(no)
Schedule
Defined
(yes)
□
(no)
000
Holiday
Schedule*
000- 252 = Schedule Number
000
Holiday
Schedule*
000- 252 = Schedule Number
000
Holiday
Schedule*
000- 252 = Schedule Number
0
Midnight Holiday
Mode
0=Holiday takes effect only after current scheduled ends.
1=Holiday always takes effect at midnight.
000 – No access; 251– Normal holiday access schedule; 252 – Always access holiday.
D00101 – 06 Keypad Selections (left to right on keypad screen)
Default Name
Selections
Description
99:90 99:90
(00:00) (00:00)
(Start) (Stop)
Schedule starting time
and stopping time.
Time Values: 00:00 = Midnight
up to 23:50 = 11:50 p.m.
Entering 99:90 in Start and Stop
will disable the schedule.
–
(no)
7 days of the
week starting
with Sunday
Weekdays that
schedule applies.
(yes)
□
(no)
Sun – Sat in which a schedule is in
effect.
Assign the schedule number to an area in A0xx03.
·
000
·
000
·
000
·
0
Save D001
00
00
·
00
·
0 mm
·
dd
···
Save H001
00