Figure 6.20 die protection screen – LINK Systems OmniLink II Press Automation Control User Manual
Page 126
August 30, 2002 Manual Version 1.0
6.21
Section 6.6 Configuration
In order for the Digital Die Protection and Process Monitor to be recognized by the OmniLink II Press
Automation Control, a Device Configuration must be performed. This process is described in Section
4.1. It is important that all Digital Die Protection and Process Monitors be assigned a module number.
After all module numbers have been assigned, the Die Protection Module must be selected from the
Device Configuration menu.
After configuring the system to recognize the Digital Die Protection and Process Monitor module(s), the
Die Protection Screen can be accessed on the OmniLink II operator Terminal. The Die Protection
Screen can be entered from the Main Menu by selecting the DIE PROTECTION softkey. The Die
Protection Screen is shown in Figure 6.20.
The Digital Die Protection and Process Monitor system should be configured before being put into
operation. This configuration allows the user to select the manner that the system can be reset and
bypassed. The user is encouraged to look at all possible configuration options, and then choose the
options that best fit his applications.
To enter the Configuration screen, place the Run/Program key switch in the Program position, then
select the CONFIGURE softkey. A popup box which requests that the user enter the user configuration
code, highest order user password. After entry of the correct code, the Die Protection System
Configuration screen will appear. This screen is shown in Figure 6.21.
Stroke
Mode
Drive
Speed
Stroke
Speed
SPM
SPM
0
0
Order
Counter
SYSTEM STATUS
Counter OFF
Die
Protection
CHANGE
SETTING
EXIT
0
0
Program/Run Switch
TOP
Production
BYPASS
ON/OFF
NEXT
PAGE
180
0
270
90
Ch Channel Type
Description
Status
State
CONFIGURE
BYPASS 20
STROKES
CHANNEL
DIAGS
RESET
ERRORS
1
2
3
4
5
6
7
8
Static
Static
1 Part Detector Edge
In Position
Cyclic
Cyclic
Cyclic
Cyclic
Stock Buckle
End of Stock
Part Detector
Feed Complete
Left Front Stripper
Right Front Stripper
Left Rear Stripper
Right Rear Stripper
OK
OK
OK
OK
OK
OK
OK
OK
Off
On
Off
Off
Off
Off
Off
Off
Module 1, Channel 5 Details
System Status: OK
Module Status: OK
Channel
Status
Ok
Input Type:
Stop Type:
Bypassed:
Delay Time:
Delay Strokes:
Window On:
Window Off:
Normally Off
Top Stop
No
0 msecs
0 strokes
154º
213º
BYPASS
SETUP
Figure 6.20 Die Protection Screen