Figure 6.20 die protection screen – LINK Systems OmniLink II Press Automation Control User Manual

Page 126

Advertising
background image

August 30, 2002 Manual Version 1.0

6.21

Section 6.6 Configuration

In order for the Digital Die Protection and Process Monitor to be recognized by the OmniLink II Press
Automation Control, a Device Configuration must be performed. This process is described in Section
4.1. It is important that all Digital Die Protection and Process Monitors be assigned a module number.
After all module numbers have been assigned, the Die Protection Module must be selected from the
Device Configuration menu.

After configuring the system to recognize the Digital Die Protection and Process Monitor module(s), the
Die Protection Screen can be accessed on the OmniLink II operator Terminal. The Die Protection
Screen can be entered from the Main Menu by selecting the DIE PROTECTION softkey. The Die
Protection Screen is shown in Figure 6.20.

The Digital Die Protection and Process Monitor system should be configured before being put into
operation. This configuration allows the user to select the manner that the system can be reset and
bypassed. The user is encouraged to look at all possible configuration options, and then choose the
options that best fit his applications.

To enter the Configuration screen, place the Run/Program key switch in the Program position, then
select the CONFIGURE softkey. A popup box which requests that the user enter the user configuration
code, highest order user password. After entry of the correct code, the Die Protection System
Configuration screen will appear. This screen is shown in Figure 6.21.

Stroke

Mode

Drive

Speed
Stroke
Speed

SPM

SPM

0
0

Order

Counter

SYSTEM STATUS

Counter OFF

Die
Protection

CHANGE
SETTING

EXIT

0

0

Program/Run Switch

TOP

Production

BYPASS

ON/OFF

NEXT

PAGE

180

0

270

90

Ch Channel Type

Description

Status

State

CONFIGURE

BYPASS 20

STROKES

CHANNEL

DIAGS

RESET

ERRORS

1

2

3

4

5

6

7

8

Static

Static

1 Part Detector Edge

In Position

Cyclic

Cyclic

Cyclic

Cyclic

Stock Buckle

End of Stock

Part Detector

Feed Complete

Left Front Stripper

Right Front Stripper

Left Rear Stripper

Right Rear Stripper

OK

OK

OK

OK

OK

OK

OK

OK

Off

On

Off

Off

Off

Off

Off

Off

Module 1, Channel 5 Details

System Status: OK

Module Status: OK

Channel

Status

Ok

Input Type:

Stop Type:

Bypassed:

Delay Time:

Delay Strokes:

Window On:

Window Off:

Normally Off

Top Stop

No

0 msecs

0 strokes

154º

213º

BYPASS

SETUP

Figure 6.20 Die Protection Screen

Advertising