Figure 6.23 die protection setting screen – LINK Systems OmniLink II Press Automation Control User Manual
Page 130
August 30, 2002 Manual Version 1.0
6.25
Section 6.7.1 Channel Settings
The channel settings define the monitoring type of the channel and the parameters associated with the
channel type. The Die Protection screen is shown in Figure 6.22. The screen displays channel type,
description, status, and sensor state for eight channels. Additional information specific for one channel,
channel 5 in Figure 6.22, is displayed in the bottom section of the screen. The additional information
includes the channel type, stop type, bypassed state, and other information specific to the channel type.
The information on the Die Protection screen is view only information. Channel setting cannot be
changed on this screen.
In order to change channel settings, the CHANNEL SETTINGS softkey must be selected. The Die
Protection Settings screen will be displayed. This screen is shown in Figure 6.23.
The channel settings can by changed by a user who has gained access control. See Section 3.9 for
information concerning access control. There are several items that can be programmed on this screen.
The item list changes depending on the type of channel logic that is selected. In Figure 6.24 a Cyclic
channel type is selected. The remaining items are all associated with Cyclic type inputs. In addition, the
help screens are specific for logic type and for the highlighted parameter. The following sections
contain a description of all possible items that may appear on the Die Protection Setting screen. Some
of these items will not appear on all screens, because they do not apply to the selected channel type.
Section 6.7.1.1 Channel Types
The channel type can be selected from the following listing.
Stroke
Mode
Drive
Speed
Stroke
Speed
SPM
SPM
0
0
Order
Counter
SYSTEM STATUS
Counter OFF
DP Chan
Settings
CHANGE
SETTING
EXIT
0
0
Program/Run Switch
TOP
Production
NEXT
CHANNEL
INCREASE
OFF ANGLE
PREVIOUS
CHANNEL
DECREASE
OFF ANGLE
INCREASE
ON ANGLE
DECREASE
ON ANGLE
Module: 1 Channel: 1
Channel Type:
Description:
Input Type:
Stop Type:
Bypassed:
Delay Strokes:
Window ON:
Window OFF:
270
0
180
90
Cyclic
Right Stripper
Normally Off
Cycle Stop
No
0
150°
210°
Help
Sets the type of logic
to apply to the
channel.
Cyclic - Normally Off
Used to monitor events that occur
once per machine cycle. The input
must be On somewhere in the timing
widow and Off somewhere in the
stroke.
Figure 6.23 Die Protection Setting Screen