LINK Systems OmniLink II Press Automation Control User Manual

Page 99

Advertising
background image

August 30, 2002 Manual Version 1.0

5.16

higher than 80 SPM when INCH mode is selected. If the press control is configured for fixed setup
(INCH) mode speed, a message on the speed screen informs the operator that “Setup speed is fixed at 80
SPM”

As shown in Figure 5.7, both drive speed, (SPM), and motor current, (% Load), are displayed in numeric
and bar graph formats. The SPM bar graph ranges from 0 SPM to the maximum strokes/minute of the
press. The % Load bar graph ranges from 0 to 200 %.




















Figure 5.7 Motor Speed Adjustment


If “motor speed adjust” is restricted to Program Mode in the configuration menu, the user must use the
Key/Code Access Mode configured for his system to access Program Mode in order to adjust speed.
Key/Code Access mode to Program Mode is described in Section 3. If the user accesses Program Mode
by using the password system, the user must be configured to have permission to change motor speed.

Motor speed can be changed by either entering a new value or by using the SPM UP and SPM DOWN
softkeys. To enter a new Motor speed value, depress the CHANGE NUMBER softkey and enter the
new value from the numeric keypad. After the correct motor speed value is entered, press the ENT key.

Section 5.5 Quick Access (ACC key)

The upper right hand key, ACC, can be used from any screen view the Quick Access screen. This
screen is shown in Figure 5.8.

Stroke

Mode Single Stroke

Drive

Speed
Stroke
Speed

SPM

SPM

200

0

Order

Counter

PC STATUS

Counter OFF

MOTOR
SPEED

CHANGE
NUMBER

SPM
UP

SPM
DOWN

0

0

SPM
200

% LOAD
161

Ready to Stroke

TO P

EXIT

Motor Speed . . . . . . . 200 SPM

Inch Mode Speed is Fixed at . . . . . . 50 SPM
M aximum Single Stroke Speed is . . 250 SPM

Advertising