LINK Systems OmniLink II Press Automation Control User Manual

Page 77

Advertising
background image

August 30, 2002 Manual Version 1.0

4.28



















Figure 4.14 Code Entry Screen to Zero Stroke Count


Entering the two digit code sent for zero stroke count sent separately from your unit for security
purposes and pressing the ENT(ER) key will set the stroke counter to zero.

Section 4.2.4.3 Key/Code Access Configuration

As described in Section 3, the OmniLink II Press Automation Control provides a user configurable
security system to limit access to system settings and actions to those authorized by the employer. The
configuration menu of the OmniLink II Press Automation Control is used to select how settings and
other operations, such as reset of faults, job storage and job recall may be done and who may perform
these actions. Settings, reset, bypass, and job storage actions fall into four access categories:

1. Those parameter settings that may be made only in the Configuration Menus, which can only be

accessed by a person(s) using the Program/Run key and the highest user level password, the User
Configuration Code. These settings include those settings that are based on machine characteristics
such as stroke length, top stop angle, etc., and those settings that relate to safety issues, such as brake
monitor limits.


2. Configuration settings made in the configuration menu at the user’s discretion to either allow certain

reset/bypass actions to be made by anyone at any time, or to require a key/code permission to restrict
access to reset/bypass functions to those persons specifically authorized by the user. Die protection
reset or bypass is an example of actions that could be restricted or not.


3. Configuration settings made in the PLS Configuration Menu to choose whether settings for

individual channels of a PLS (programmable limit switch) are restricted from being changed even by
persons who have key/code access to make settings for PLS channels. Of course the person with
key/code access could still make settings for those PLS channels that are not restricted in the
configuration menu.

Stroke

Mode

Drive

Speed
Stroke
Speed

SPM

SPM

0
0

Order

Counter

SYSTEM STATUS

Counter OFF

8

0

OK

Top Disp

Config

CHANGE
SETTING

EXIT

Top Display Area Configuration

When in a Setup Mode
(Inch, Timed Inch, Etc. )

When in a Production Mode
(Single Stroke, Cont. , Etc. )

Date :

Time :

4/24/2002

10:20:46 AM

Rod/Stroke Units :

Rod Length :

Stroke Length :

in

0.000 in

0.000 in

Default Language :

English

Enter Code # :