background image

Installation

Page 14

MDE-4351A Gasboy ATC Kits 039086 and 039087 Installation Manual • February 2006

28

Remount the LP-70 Polycase box cover removed in step 1.

29

Using two of the crimp splices, connect the two yellow wires extending from the bottom of the
IS barrier mounting stud to the two blue wires attached to the single probe connector assembly.

30

Using two OM0205 caps or suitable-size wire nuts (OM0205 caps or wire nuts are not part of
the kit.), cap the end of the two green wires extending from the bottom of the IS barrier.

31

In the kit, locate the following: (See

Figure 1

for parts identity)

• W199 probe assembly
• BC407 Thermowell
• 235-C Thermowell Plug
• BC546 Adapter

32

Underneath the shelf (where the IS barrier is mounted), locate the two plugs in the hydraulic
coupling (

Figure 11

).

Figure 11: Probe Assembly Mounting Location

33

Using the appropriate size Allen wrench, remove the two plugs.

4

Not used

5

Pulser Multiplier

ON for 9850, OFF for 9852/9853

6

Number of Probes

ON for two (2) probes, OFF for one (1) probe

7

Pulser Adder

ON for 9840

8

ATC

ON for ATC ON, OFF for ATC OFF

DIP Switch Settings

Switch
Number

Switch Function

Settings

Plugs