Installation

Page 8

MDE-4351A Gasboy ATC Kits 039086 and 039087 Installation Manual • February 2006

Installation

Use electrostatic discharge (ESD) precautions to place yourself at a neutral

static-free potential by touching an unpainted metal surface and by using a wrist
strap connected to a grounded metal frame or chassis.

Preparation

1

Request permission from the manager/owner to remove power from the unit and then remove
power using normal procedures. Observe the lockout/tagout safety procedures.

2

Make sure you have the proper kit for the model dispenser to be retrofitted.

3

Using the proper key for the unit, unlock and remove the doors from both sides of the unit.
Place doors in a safe place to prevent damage or scratches.

4

Using a cross-tip screwdriver, at side 1 of the unit, loosen the two screws (one on each side of
the display cover), spring the screw holders and screws out from the display cover and pull the
display cover forward. The cover will pivot down in a horizontal position allowing access to
the electronics section of the unit.

Installing the 039086 ATC Kit in Single Unit

1

In the kit, locate the LP-70 Polycase box with SK449C PCB mounted inside. Remove the four
mounting screws securing the cover and remove the cover from the box. Save screws and
cover for reinstalling later.

2

Peel the protective cover from the mounting sponge (on the back of the polycase box) and
mount the box as shown in

Figure 3

. Mount approximately 1/2-inch up from shelf (1/2-inch

clearance underneath shelf).

Figure 3: Mounting the LP-70 Polycase Box

Approximately 1/2-inch
Clearance