4 bus list, 5 module list, 6 list input configuration and status – Nevion Multicon MRP User Manual
Page 37
Modular Routing Protocol - MRP
Rev. L
nevion.com | 37
9.4 Bus list
A router is connected to the controller on some physical connection. This is called a bus in
this protocol. A bus can have zero to many routers connected. This command lists each
router in the controller and which bus they are connected to.
Command:
blist[*CC]<LF><LF>
Response:
? "blist"<LF>
<router_bus_relations>
[*CC<LF>]
<LF>
Where
<router_bus_relations>=<router_bus_relation>[
<router_bus_relations>]
<router_bus_relation>=r<rno> b<busno>[ {local|remote}[
<interface_type>][ <protocol>]<LF>
<interface_type>={internal|serial|tcpip[ <ip>:<port>]}
<protocol>={ncb|modular|triton|probel-sw-p-88|leitch-pass-through}
9.5 Module list
Some routers are built up by modules. This command lists all modules in this router.
Command:
mlist[*CC]<LF><LF>
Response:
? "mlist"<LF>
m<module> b<busno> <modulename>
9.6 List input configuration and status
Lists each input's configuration and status.
Command:
sin b<busno>[*CC]<LF><LF>
Response:
? "sin b<busno>"<LF>
[in b<busno> m<module> <input>
[eq={unknown|enabled|bypass}]
[signal={unknown|no|yes}]
<LF>]
[in …]
[*CC<LF>]
<LF>