9.4 Bus list

A router is connected to the controller on some physical connection. This is called a bus in
this protocol. A bus can have zero to many routers connected. This command lists each
router in the controller and which bus they are connected to.

Command:

blist[*CC]<LF><LF>

Response:

? "blist"<LF>

<router_bus_relations>

[*CC<LF>]

<LF>

Where

<router_bus_relations>=<router_bus_relation>[
<router_bus_relations>]

<router_bus_relation>=r<rno> b<busno>[ {local|remote}[
<interface_type>][ <protocol>]<LF>

<interface_type>={internal|serial|tcpip[ <ip>:<port>]}

<protocol>={ncb|modular|triton|probel-sw-p-88|leitch-pass-through}

9.5 Module list

Some routers are built up by modules. This command lists all modules in this router.

Command:

mlist[*CC]<LF><LF>

Response:

? "mlist"<LF>

m<module> b<busno> <modulename>

9.6 List input configuration and status

Lists each input's configuration and status.

Command:

sin b<busno>[*CC]<LF><LF>

Response:

? "sin b<busno>"<LF>

[in b<busno> m<module> <input>

[eq={unknown|enabled|bypass}]

[signal={unknown|no|yes}]

<LF>]

[in …]

[*CC<LF>]

<LF>