9.13 Set environment alarm limits
Set environment alarm limits
<command> ::= 'env' 'b'<busno> 'm'<module> 'nom'|'ul'|'ll'
['temp='<value>]
['voltage1='<value>['mV'|'V']]['voltage2='<value>['mV'|'V']]
['voltage3='<value>['mV'|'V']]['voltage4='<value>['mV'|'V']]
['fan1='<value>['rpm']]['fan2='<value>['rpm']]
['timer1='<value>]['timer1='<value>]
<response> ::= [<env_info> {<LF><env_info>}]
<env_info> ::= 'env' 'b'<busno> 'm'<module> 'nom'|'ul'|'ll'
['temp='<value>]
['voltage1='<value>]['voltage2='<value>]
['voltage3='<value>]['voltage4='<value>]
['fan1='<value>]['fan2='<value>]
['timer1'=<value>]['timer1='<value>]
Where:
nom
List nominal values
ul
List upper limit
ll
List lower limit
env b1 m0 nom voltage1=1700mV
? "env b1 m0 nom voltage1=1700mV"
env b1 m0 nom voltage1=1700mV voltage2=3300mV voltage3=5000mV
voltage4=12000mV
9.14 List environment status
List the environment status.
<command> ::= 'senv' ['stat'|'nom'|'ul'|'ll']
<response> ::= [<env_info> {<LF><env_info>}]
senv
? "senv"
env b1 m0 temp=38.00 voltage1=1794mV voltage2=3222mV
voltage3=5002mV voltage4=11860mV fan1=5758rpm fan2=5756rpm
timer1=8864 timer2=8864
env b1 m1 temp=33.75 voltage1=1791mV voltage2=3193mV
voltage3=5024mV voltage4=12014mV fan1=3243rpm fan2=3239rpm
timer1=24657 timer2=24657