9.12 Monitor configuration
Configure the monitor matrix. This is only available on some crosspoint-boards.
Command:
monitor b<busno1> m<module1> <monitor1>
[restart]
[mask={none|all|[trs][[,]eav][[,]sav][[,]lnum]
[[,]lcrc][[,]ycrc][[,]ccrc]
[[,]ancs][[,]ycs][[,]ccs]
[[,]lock][[,]apcrc][[,]ffcrc][[,]vs]}]
[*CC]<LF><LF>
Response:
? "<command>"<LF>
[monitor b<busno> m<module> <monitor>
[type=edh [mask={none|all|[trs][[,]eav]
[[,]sav][[,]lnum]
[[,]lcrc][[,]ycrc]
[[,]ccrc][[,]ancs]
[[,]ycs][[,]ccs]
[[,]lock][[,]apcrc]
[[,]ffcrc][[,]vs]}]
[error_count=<count>]
[unlocked|locked] [asi] [sd|hd]
[[y|c]data_format={sdti_dvcpro|
sdti_dvcpro_ecc|
sdti_dvcam|
sdti_cp|sdti_fixed|
sdti_variable|
sdi|dvb_asi|tdm|
unknown}]
[standard={1280x720/60|1280x720/30|
1280x720/50|1280x720/25|
1280x720/24|1920x1080|
1920x1080/30|1920x1080|
1920x1080/25|1920x1080/24|
1920x1080/50|1920x1080/60|
525-line|625-line|hd|sd|unknown}]
<LF>]