E to E Timed Outputs

In some applications, you may want to precisely switch an output from a live
video feed to playback of recorded material. Since the live input will be delayed
as it passes through the Profile unit, you must set a corresponding delay on the
playback. The E to E Timed Output option sets a 16-line delay on all the system
outputs, allowing a zero-timed input to be exactly timed with a play to air
signal. To set all your Profile unit output for E to E operations:

1. Choose

Option | System Timing

or click the

System Timing

button on the

toolbar. The System Timing dialog box appears.

2. Click

E to E Timed Output

.

3. Click

Close

.

Figure 8. System Timing dialog box, E to E timed