Environmental specifications – Gateway 6400 User Manual

Page 133

Advertising
background image

124

Reference Data

Environmental specifications

The following specifications identify maximum environmental conditions. At
no time should the server run under conditions which violate these
specifications.

Network Interface

Integrated Intel 82559 PCI ethernet controller.

Video

Integrated ATI Rage-XL PCI-based VGA controller with 4 MB of PC100
SDRAM.

Expansion Slots

Seven PCI slots (two 64-bit/33 MHz and five 32-bit/33 MHz).

Power Supply

300 watts. ATX power connector for easy power cable changeover.

Certification

FCC Class A, UL, CUL, CE Mark, VCCI, CB Scheme.

Variable

Requirements

Temperature

Maximum rate of change = 10° C per hour

Nonoperating

–48.3° to 65.5° C (–55° to 150° F)

Operating

5° to 35° C (41° to 95° F); derated 0.5° C for every
1000 ft. (305 m)

Altitude

10,000 ft. max

Humidity

Nonoperating

95% relative (noncondensing) at 30° C (86° F)

Operating wet bulb Not to exceed 33° C (91.4° F) (with diskette drive or hard

disk drive)

Shock

Operating

2.0 g, 11 msec, 1/2 sine

Packaged

Operational after 30-inch free fall (cosmetic damage
might occur)

AC Input Power

100-120 V

100-120 V

, 6 A, 50/60 Hz

200-240 V

200-240 V

, 3 A, 50/60 Hz

05032.book Page 124 Monday, July 10, 2000 11:43 AM