Writing edid data to a display – Quantum Data 802BT User Manual

Page 182

Advertising
background image

172

Chapter 10

Testing EDID

5. To view parsed EDID information, press and release the

Step

key, and then turn the

Image

knob to view additional blocks and parsed data.

To query EDID information from an HDMI, DVI or VGA display via the command line:

1. Using a terminal emulator, establish a terminal session with the generator (see page

14).

2. To view the current EDID in ASCII hex format, use the

EDID?

command.

To view a specific segment of EDID, use the

I2CR?

command.

Querying the EDID from the command line enables you to create a text file with the

EDID in order to configure the analyzer to emulate the display device.

Writing EDID data to a display

You can modify the EDID in the connected display, if the EEPROM in the display is

writable.

To modify the EDID in a display:

1. Connect the display to be modified to the HDMI, DVI or VGA Tx connector on the

generator.

2. Using a terminal emulator, establish a terminal session with the generator (see page

14).

Advertising