System errors, Power-on self test messages – Quantum Data 802BT User Manual

Page 718

Advertising
background image

708

Appendix C

Error Messages

System errors

This section discusses system error messages that may be displayed by the generator

from time to time.

Power-on self test messages

The integrity of the data stored in non-volatile memory is checked every time the generator

is turned on. The following tests are performed:

1. The system configuration memory is checked. The memory remembers what the

generator was doing when it was last powered down. The memory also stores all

system wide parameters such as calibration factors and the light meter size. It is also

checked to see if it is compatible with the current version of operating firmware. If

everything is in order, then the generator goes on to step 2.

Otherwise, a “System corrupt!” message is displayed for 2 seconds. This message is

immediately followed by a “Memory blank” message, which is displayed for 2 seconds

while the format memory is re-initialized. Memory initialization involves clearing the

entire non-volatile memory and loading it with factory default data. Any and all data

created or edited by the user will be wiped out. The calibration factors are restored to

the original values used at the factory to test and calibrate the unit. The generator then

continues with step 3.

Note: System corruption is rare, and may be an indication of a bad memory backup

battery or a damaged generator.

Note: If you update the firmware EPROM in your unit, your system will appear to be

corrupt at the next power-on.

2. The remainder of non-volatile memory is checked to see if any data has been corrupted

since the last time the generator was used. This check includes each of the 300 format

storage locations. All user created custom images and test sequences are also

checked. If no problems are found, the generator goes on to step 3.

If one (or more) items have been corrupted, a message containing a tally of the

defective items is displayed for 2 seconds. A message for two corrupted items is shown

here. Please note that the checking routine does not identify the types of items (format,

Advertising
This manual is related to the following products: