Gcet, Gcet? get component error tallies – Quantum Data 802BT User Manual

Page 358

Advertising
background image

348

Appendix A Command Reference

GCET?

Get Component Error Tallies

Class

DVI signal analyzer

Description

Reads the number of errors in the red, green, and blue components along with the total

number of bad pixels.

Query syntax

GCET?

Query response

R, G, B, and bad pixels

Example

PNAU

//Pseudo-random noise generated

CR

//Stop pseudo-random noise

GCET?
0,21,0,21 //Returns 21 Green pixel errors and a total of 21 bad pixels

Related commands

PNAU

Advertising