Format errors, Invalid data error messages, Corrupt data error messages – Quantum Data 802BT User Manual

Page 720

Advertising
background image

710

Appendix C

Error Messages

Format errors

Under normal operating conditions, a properly programmed model 801GX generator

should never report any Format error messages. If you do get an error message while

loading a format it is for one of two reasons. The generator distinguishes between invalid

data, entered in one of the programming modes, and corrupted data caused by a memory

failure. In either case, the generator will shut all of its outputs off. The outputs remain off

until a valid format is loaded.

Invalid data error messages

The example on the left shows a typical invalid data error message. The top line of the

display shows the format’s storage location number and name. The bottom line shows the

error number. Error numbers will be in the range of 2000 through 2999. Different numbers

indicate what type invalid data or combination of data is causing the error.

The following pages explain the cause of each of the error numbers and offers

suggestions on how to correct the problem.

Corrupt data error messages

The example on the left shows a corrupted data error message. The top line of the display

shows the format’s storage location number and name. The bottom line shows the error

number. Error number 9450 identifies the cause of the error as corrupted data. This type

of error either indicates the signs of a failing memory backup battery or a more serious

hardware failure in the generator.

Corrupted formats can corrected by either editing them or by downloading a clean copy of

the format from a computer. The “Programming” chapter explains both methods in detail.