Video Test Generator User Guide

313

EQUF

EQUalization Flatten

Class

Format parameter setting - synchronization

Description

Determines if composite sync will have all equalization pulses removed in the vertical sync

front porch (delay) period as required by certain military HOBO and Maverik video formats.

The EQUF? query returns the current setting of EQUF.

Command syntax

EQUF mode

mode

0 = OFF

1 = ON

Query syntax

EQUF?

Query response

mode

Other required

commands

The

FMTU

command instructs the generator to use the new setting. The

ALLU

command

updates hardware to the new setting and redraws the test image.

Example

EQUF 0; ALLU // This is the default