I-View AnyNet-0401Mini Embedded NVR User Manual

Page 79

Advertising
background image

79

display on two places.

Allow all Windows User Accounts to use this application All users with different Windows

accounts can be allowed to run Witness Pro program.

Upon system failure Select PC’s reaction “Restart program” and “Reboot system” from the

drop-down menu when NVR system is abnormal. For example: Select “Restart program”, the

system will automatically restart Witness Pro program when NVR system is abnormal.

Log out when no user interaction is involved for Logout the Witness Pro program when the user

is inactive NVR over the setting duration.

Exit option Select PC status “Exit program”, “Turn off”, “Log off” or “Restart” from the

drop-down menu after exiting Witness Pro program. For example: Select “Turn off”, the system

will automatically shut down after exiting Witness Pro program.

Auto login The NVR will automatically login by saved username and password in Witness Pro

after reboot.

NetCom Module:

Model: Select the type of control board for the PTZ camera, D/I and D/O devices based on the

installed models.

Checksum: It depends on the type of Speed dome camera. Please refer to the manual of Speed

dome camera.

Com Port: You must select “Auto” from the draw menu of “Com Port “icon when you want

to enable the function of Netcom module.

Baud rate: Select a correct Baud rate to control the Speed dome camera or P/T/Z camera from

Witness NVR board (Default setting is 9600 bps).

You must select “9600” baud rate, enable Checksum icon, and select “Pelco P” or “FastCam

V2” or “SDCI-220” when you install I-View’s FastCam III Speed dome camera series.

PAC-080M Amplifier: You need to connect the PAC-080M public address sever with the

NVR/NVR before enable this function. Select the “Auto” from the drop-down menu of “ Com

port”. If the setup is correct that the P.A. configuration tab will be enable.

Advertising