Replacing the Controller Cache Battery Pack

WARNING:

There is a risk of explosion, fire, or personal injury if the battery

pack is replaced incorrectly or mistreated. To reduce the risk:

Do not attempt to recharge the battery outside of the controller.

Do not expose to water, or to temperatures higher than 60°C.

Do not abuse, disassemble, crush, puncture, short external contacts, or

dispose of in fire or water.

Replace only with the spare designated for this product.

Array Accelerator battery disposal should comply with local regulations.

Alternatively, return them by established parts return methods to

Hewlett- Packard Corporation for disposal.

Caution:

It is important to follow these instructions when replacing

components in the MSA1000. If the procedure is done improperly, it is

possible to lose data or damage equipment. Refer to the “

Electrostatic

Discharge

” appendix for important information on using the proper

procedures.

To remove the old NiMH battery pack:

1. Remove the MSA1000 Controller Cache, as instructed in the previous

section, “

Replacing the MSA1000 Controller Cache

.”

2. Push down on the bottom clip of the battery pack, attached near the lower

corner of the Array Accelerator.

See

Figure 6

for an illustration.