HP StorageWorks 1000 Modular Smart Array User Manual

Page 39

Advertising
background image

Controller Display Messages

39

MSA1000 Controller User Guide

51 REDUNDANCY
FAILED I/O
REQUEST ERROR

Error

While either attempting to

enter redundant mode or

already operating in

redundant mode, one of

the array controllers

encountered an error while

sending I/O between the

two array controllers over

the communication channel

between them. Redundancy

is disabled at this time.

If the MSA1000 is currently

involved in host I/O,

remove the

standby

array

controller, wait 10 seconds,

and then reinsert it insuring

that it is fully seated in the

chassis.

If this does not resolve the

issue then wait until

down-time is available.

Power off the MSA1000,

remove both array

controllers, and reinsert

them insuring they are fully

seated in the chassis.

Should the issue persist

please contact HP support.

52 REDUNDANCY
FAILED PCI BUS
ERROR

Error

While either attempting to

enter redundant mode or

already operating in

redundant mode, one of

the array controllers

encountered a PCI bus

error on the communication

channel used between the

two array controllers.

Redundancy is disabled at

this time.

If the MSA1000 is currently

involved in host I/O,

remove the

standby

array

controller, wait 10 seconds,

and then reinsert it insuring

that it is fully seated in the

chassis.

If this does not resolve the

issue then wait until

down-time is available.

Power off the MSA1000,

remove both array

controllers, and reinsert

them insuring they are fully

seated in the chassis.

Should the issue persist

please contact HP support.

53 REDUNDANCY
FAILED NO SECOND
CONTROLLER

Error

While operating in

redundant mode, one of

the array controllers was

removed. Redundancy is

disabled at this time.

Reinsert the missing array

controller insuring that it is

fully seated in the chassis.

Table 3: LCD Message Descriptions

Message

Type

Description

Action

Advertising