Controller Display Messages

37

MSA1000 Controller User Guide

47 REDUNDANCY
FAILED CACHE
SIZE MISMATCH

Error

Both array controllers must

have the same size of

cache memory for them to

successfully enter

redundant mode.

If the MSA1000 is currently

involved in host I/O,

remove the

standby

array

controller, add or remove

cache memory as needed,

wait 10 seconds, and then

reinsert it insuring that it is

fully seated in the chassis.

If this does not resolve the

issue then wait until

down-time is available.

Power off the MSA1000,

remove both array

controllers, add or remove

cache memory as needed

on both, and reinsert them

insuring they are fully

seated in the chassis.

Should the issue persist

please contact HP support.

48 REDUNDANCY
HALTED FIRMWARE
CLONED

Informational

Both array controllers must

be running the same

version of firmware for

them to successfully enter

redundant mode. A

process called firmware

cloning has been

successfully completed in

order to make them both

the same firmware level.

The

standby

array

controller will now be

restarted automatically so

they can attempt to achieve

redundancy again.

Table 3: LCD Message Descriptions

Message

Type

Description

Action