Controller Display Messages

32

MSA1000 Controller User Guide

LCD Message Descriptions

The following table contains the defined messages and their components.

Table 3: LCD Message Descriptions

Message

Type

Description

Action

00 ARRAY
CONTROLLER
FIRMWARE VER
<version>

Informational

Displays the current version

of the firmware running on

the array controller.

01 MSA1000
STARTUP COMPLETE

Informational

The array controller has

completed its power on

sequence and is now

operational.

02 ENABLE VOLUME
<n>? ‘<’=NO,
‘>’=YES

User Input

An issue has been found

with a configured volume

that may result in data loss.

The exact nature of the

issue will be detailed in a

previous display message.

Selecting the

no

option will

result in the volume being

disabled so the user can

attempt to fix the issue.

Selecting the

yes

option

will result in the volume

being enabled regardless

of the issue.

03 CRITICAL
LOCK-UP
DETECTED.
CODE=<n>h

Error

A critical error has been

detected by the array

controller firmware. In

order to prevent any

possible data loss, the

firmware has entered a

lock-up state. The code

contains engineering

specific information about

the lock-up condition. HP

support should be

contacted.

Remove the failing array

controller, wait 10 seconds,

and then reinsert it insuring

that it is fully seated in the

chassis.

Should the issue persist

please contact HP support.

04 ENABLE
VOLUMES ?
‘<’=NO, ‘>’=YES

User Input

An issue has been found

with all of the configured

volumes that may result in

data loss. The exact nature

of the issue will be detailed

in a previous display

message.

An issue has been found

with all of the configured

volumes that may result in

data loss. The exact nature

of the issue will be detailed

in a previous display

message.