HP StorageWorks 1000 Modular Smart Array User Manual

Page 60

Advertising
background image

Controller Display Messages

60

MSA1000 Controller User Guide

515 FIBRE DEVICE
HARDWARE FAILURE

Error

The fibre device that is

installed in the MSA1000

fibre bay was not

recognized by the array

controller.

Verify the fibre device is

supported by the

MSA1000 by checking the

documentation that came

with it. If it is supported

then remove the fibre

device, wait one minute

and then reinsert it insuring

it is fully seated in the

chassis. Wait one minute

and check the LCD to see if

a new copy of this error

message is created. The

service indicator LED on

the back of the switch

should turn solid green if

the device is operating

normally. The service

indicator LED will flash

amber if it has failed

again.

Should the issue persist,

please contact HP support.

516 FIBRE
SUSBYSTEM LINK
FAILURE

Error

There is no active fibre

connection to this

MSA1000 array controller

(Laser OFF).

If the Fibre connection is a

direct-connect from an

HBA to the MSA1000, this

message is expected when

the server is powered off or

restarted.

Power on the server and

load the HBA drivers.

If the status does not

change to OK, check

cables, fibre bay board,

SFP, and HBA.

517 FIBRE
SUBSYSTEM LINK
OK

Informational

There is an active fibre

connection to this

MSA1000 array controller

(Laser On).

This message is only

displayed when preceded

by message 516.

Table 3: LCD Message Descriptions

Message

Type

Description

Action

Advertising