HP StorageWorks 1000 Modular Smart Array User Manual

Page 35

Advertising
background image

Controller Display Messages

35

MSA1000 Controller User Guide

41 REDUNDANCY
ACTIVE ACTIVE
CONTROLLER

Informational

The array controllers are

now in redundant mode

and this array controller is

active

which means that it

is allowed to access the

configured volumes on the

MSA1000.

42 REDUNDANCY
ACTIVE STANDBY
CONTROLLER

Informational

The array controllers are

now in redundant mode

and this array controller is

standby

which means that

it can be made

active

should the current

active

array controller fail,

assuming you have all

cables, I/O module or

embedded switch installed.

43 REDUNDANCY
FAILED HARDWARE
FAILURE

Error

While either attempting to

enter redundant mode or

already operating in

redundant mode, one of

the array controllers

encountered a hardware

failure on the

communication channel

between the two array

controllers. Redundancy is

disabled at this time.

If the MSA1000 is currently

involved in host I/O,

remove the

standby

array

controller, wait 10 seconds,

and then reinsert it insuring

that it is fully seated in the

chassis.

If this does not resolve the

issue then wait until

down-time is available.

Power off the MSA1000,

remove both array

controllers and reinsert

them insuring they are fully

seated in the chassis.

Should the issue persist

please contact HP support.

Table 3: LCD Message Descriptions

Message

Type

Description

Action

Advertising