Chapter 4 ___________________________________________________________ Troubleshooting

VAISALA______________________________________________________________________ 131

The measurement TAMeasQMH101_1 is defined in the setup file. The
command with the raw parameter produces the following response:

/ > LASTVAL TAMeasQMH101_1 unconv
Status:1 Value:109.508383

When the value in the report changes to ////, you can check the value. In
the following case, the probe is not connected:

/ > LASTVAL TAMeasQMH101_1 TA
Status:2 Value:-231.156481

When the value is invalid, check the sensor status value and refer to

Table 13 on page 72

:

/ > LASTVAL TAMeasQMH101_1 status
Status:1 Value:0

Warnings and Errors

There may be some problems if you see either of the following prompts:

/ E>
/ W>

/ E>

means that there are errors, and

/ W>

means that there are

warnings.

where
Status:1

=

Value is valid.

Value:109.508xxx =

Unconverted value [ohms] of PT100
measurement

where
Status:2

=

Value is invalid.

Value:-231.15xxxx =

Temperature measurement indicating that the
probe is not connected

where
Status:1

=

Status field in the output is the value status.

Value:0

=

Value field shows the sensor status.