Dual rs-485 module dsi486, version b, Figure 69, Rs-232 jumper settings – Vaisala Hydromet Data Collection Platform User Manual

Page 148: Table 35, Jumper settings for dsi486-b

Advertising
background image

User's Guide ______________________________________________________________________

146 __________________________________________________________________M210784EN-E

Dual RS-485 Module DSI486,
Version B

The later module version, DSI486-B, has otherwise the same features as
module DSI486-A, but its jumper settings are slightly different. The
settings have been simplified to make the module easier to use. Notably,
jumpers X4 and X5 still select the termination resistors for channels A
and B, respectively, only their locations have been moved a bit (see

Figure 69 on page 146

).

0903-024

Figure 69

RS-232 Jumper Settings

Jumpers X3 and X6 are used to select between the RS-485 and RS-232
modes for channel B, but their settings have been simplified. The
jumper positions are described in

Table 35 on page 146

.

Table 35

Jumper Settings for DSI486-B

Jumper

Connected
Pins

Function

X3

1-2

Channel B RS-232 mode

2-3

Channel B RS-485 mode (default)

X6

1-2

Channel B RS-485 mode (default)

2-3

Channel B RS-232 mode

X4

1-2

Channel A RS-485 line terminating resistor
active

X5

1-2

Channel B RS-485 line terming resistor active.
Do not use in RS-232 mode

Advertising