Chapter 3 _______________________________________________________ AWS Client Software

VAISALA_______________________________________________________________________ 89

Use the following commands in the service connection to change the
flagging:

enable <Measurement name>

disable <Measurement name>

Examples:

>\ disable RHMeasQMH102_1
>\ disable TAMeasQMH102_1
>\ disable WMS302_1
>\ enable PWD22_1

Upon successful completion of the commands, the response is as
follows:

Successfully disabled

or

Successfully enabled

Any other returned values indicate an error.

When the measurement input is disabled:

-

All output values other than status have undefined values.

-

Sensor status shows

disabled

; refer to the list of the sensor

statuses in

Table 13 on page 72

.

-

Value status shows

INVALID

and

NOT AVAILABLE

.

where
enable

=

Enables the measurement inputs or sensors

disable

=

Disables the measurement inputs or sensors

Measurement name =

Measurement name in Lizard

NOTE

For sensors that use more than one input channel, you need to enter
separate commands for each measurement. For example, you need to
control separately the TA and RH measurements of the QMH air
temperature and relative humidity sensor.