Videotec DCT User Manual

Page 116

Advertising
background image

6.11.7

Special codes

Some parameters can be configured by inserting a special code.
Go to the page for inserting special codes (see § 6.1.5 - Layout of the configuration menus, page 76) and
insert the numeric values using the keypad.

Code

Function

0

PAN position 0.

SPEED CURVES

11

First speed curve (speed values: 1, 5, 10, 20, 30, 45, 63).

12

Second speed curve (speed values: 1, 10, 20, 30, 40, 50, 63).

13

Third speed curve (speed values: 10, 15, 20, 25, 30, 45, 63).

14

Fourth speed curve (default) (speed values: 29, 37, 45, 50, 55, 59, 63).

15

Fifth speed curve (speed values: 10, 15, 20, 30, 40, 50, 63).

16

Sixth speed curve (can be customised by the user, but has default values:
10, 15, 20, 30, 55, 100, 255).(*)

8ZZZ

ZZZ = 000 ÷ 255: speed value. (*)

900X

X = 1 ÷ 7: Speed No. associated with speed value ZZZ.

910X

X = 1 ÷ 7: dome movement test at fixed speed No. X.
Move the joystick to break off the test.

Example

8007”: speed value equal to 7 (ZZZ = 007)
9001”; the speed value of 7 is assigned to speed No. 1 (X = 1)

...insertion of speed values for speed Nos. 2, 3, 4, 5 and 6...

8138”: speed value equal to 138 (ZZZ = 138)
9007”; the speed value of 138 is assigned to speed No. 7 (X = 7)
Now we test speed No. 7:
9107”: the dome moves at the fixed speed of 138 (X = 7)
16”: from now on every time the joystick is moved the dome will move at the speed that
the user has assigned to the sixth curve (X = 16)

(*) The Pelco D protocol accepts a maximum speed value of 63. Correct operation cannot be guaranteed for
higher speed settings.

ZONE

20

Start the SCAN of the zone.

21

End the SCAN of the zone.

10X

X = 1 ÷ 8: Set the start of the zone.

20X

X = 1 ÷ 8: Set the end of the zone.

AUTOFOCUS

40

AUTOFOCUS On.

41

AUTOFOCUS Off.

42

Automatic AUTOFOCUS On.

AUTOIRIS

50

AUTOIRIS On.