Videotec DCT User Manual

Page 85

Advertising
background image

Code

Function

49XX

XX = 00 ÷ 28 (*): stop wiper

50XX

XX = 00 ÷- 28 (*): stop pump

51XX

XX = 00 ÷ 28 (*): stop lighting

52XX

XX = 00 ÷- 28 (*): stop heater

53XX

XX = 00 ÷- 28 (*): stop fan

60XX

XX = 00 ÷ 37: return to Home position (Preset position No. 1)
00: function disabled; 01 ÷ 06: from 5 to 30 seconds (step = 5 seconds); 07: 45 seconds;
08 ÷ 16: from 1 to 9 minutes (step = 1 minute); 17 ÷ 26: from 10 to 55 minutes (step= 5
minutes); 27 ÷ 32: from 60 to 110 minutes (step = 10 minutes); 33 ÷ 37: from 2 hours to 4
hours (step = 30 minutes)

(*): 00: continuous; 01 ÷ 04: from 5 to 20 seconds (step = 5 seconds); 05: 30 seconds; 06: 45 seconds; 07 ÷
11
: from 1 to 5 minutes (step = 1 minute); 12: 10 minutes; 13: 15 minutes; 14: 30 minutes; 15: 45 minutes;
16 ÷ 27: from 1 to 12 hours (step = 1 hour); 28: 24 hours

DIGITAL ZOOM

90

Off

91

On

92

4x

93

16x

SHUTTER

200

Off

201

On

202

Automatic

High Speed

211

Flickerless (PAL: 1/120 s,

NTSC: 1/100 s)

212

1/125 s

213

1/250 s

214

1/500 s

215

1/1000 s

216

1/2000 s

217

1/4000 s

218

1/10000 s

Slow

221

PAL: 1/25 s

NTSC:1/30 s

222

PAL:1/12.5 s NTSC: 1/15 s

223

1/8 s

224

1/4 s

225

1/2 s

226

1 s

227

2 s

228

PAL: 5 s

NTSC:4 s