EDXtreme User Instructions

Holdoff Seconds:

Once the unit has recorded this overload, how
much time will pass before this unit will re-arm
and allow to record the overload again.

Comm Port:

This allows you to choose where to export the
"ON PRINT" logged data.

a. EDX = Cell

b. COMM = Com1

c. RADIO = Future development

d. Disabled = to turn off

ID

An operater can key in either a User ID number or a Lift ID assigned to a
particular product. This is a numeric number only and can be any number
from 1 to 65,000. (if you want to turn the ID off, key in 0).

Send

This will export/send the Log information out the configured port.

Clear

This will clear any data in the Log mode. Clearing "On Lift", "Timed" and
"Overload" stored data.

Note: All Log Modes will record Date and Time along with it's force and peak reading.