Figure 6 - Minimum Mantel Clearances Without Using Hood

Minimum

Noncombustible

Material

Minimum

Noncombustible

Material Height

Distances to

Underside of

Mantel

Top of

Fireplace

Opening

Underside

of Mantel

Shelf

Mantel Shelf

12"

(

A)

18" 20" 22" 24"

All

minimum

distances

are in

inches

2

1

/

2

"

6"

8"

10"

INsTallaTIoN

Continued

Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace

Figure 7 - Minimum Mantel Clearances When Using Hood

Minimum

Noncombustible

Material

8"

Min.

12" 15" 18" 20"

2½"

6"

8"

10"

12"

Distances to

Underside of

Mantel

Hood

(GA6050 or

GA6053)

Top of

Fireplace

Opening

Underside

of Mantel

Shelf

Mantel Shelf

Noncombustible
Material Distance
(A)

Requirements for Safe Installation

12" or more

Noncombustible material OK

Between 8" and
12"

Install fire place hood accessory ( see
Accessories, page 25).

Less than 8

Noncombustible material must be ex-
tended to at least 8". See Between 8"
and 12"
, above. If you cannot extend
material, you must operate heater
with flue damper open.