Continued

Figure 13 - Equipment Shutoff Valve

Open

Closed

Equipment
Shutoff Valve

Figure 15 - Checking Gas Joints for

Propane/LP Gas

Control Valve Location

Propane/LP
Supply Tank

Equipment Shutoff Valve

Figure 14 - Checking Gas Joints for

Natural Gas

Gas Meter

Equipment Shutoff Valve

Control Valve
Location

4. Check all joints of gas supply piping system.

Apply noncorrosive leak detection fluid to all
joints. Bubbles forming show a leak.

5. Correct all leaks at once.
6. Reconnect heater and equipment shutoff

valve to gas supply. Check reconnected
fittings for leaks.

Test Pressures Equal To or Less Than
1/2 PSIG (14" W.C.)
1. Close equipment shutoff valve (see Fig-

ure 13).

2. Pressurize supply piping system by either

opening propane/LP supply tank valve
for propane/LP gas or opening main gas
valve located on or near gas meter for
natural gas or using compressed air.

3. Check all joints from gas meter to equip-

ment shutoff valve for natural gas or
propane/LP supply to equipment shutoff
valve for propane/LP (see Figure 14 or 15).
Apply noncorrosive leak detection fluid to
all joints. Bubbles forming show a leak.

4. Correct all leaks at once.

PRESSURE TESTING HEATER GAS
CONNECTIONS
1. Open equipment shutoff valve (see Fig-

ure 13).

2. Open main gas valve located on or near

gas meter for natural gas or open pro-
pane/LP supply tank valve.

3. Make sure control knob of heater is in the

OFF position.

4. Check all joints from equipment shutoff

valve to control valve (see Figure 14 or 15).
Apply noncorrosive leak detection fluid to
all joints. Bubbles forming show a leak.

5. Correct all leaks at once.
6. Light heater (see Operation, page 15).

Check all other internal joints for leaks.

7. Turn off heater (see To Turn Off Gas to

Appliance, page 18).

ADDING EMBERS, LAVA ROCK AND
DECORATIVE LOGS

The effect of glowing embers is created by
placing ember material on the front burner.
1. Make sure the heater is OFF and has

cooled if it has been running.

2. Gently remove embers from the bag us-

ing gloves or tweezers. (This material is
a skin irritant. Gloves or tweezers are
recommended to prevent skin irrita-
tion).
Separate the pieces.

3. Add embers to front flat burner as shown

in Figure 16. (12 pieces are supplied with
24" models and 8 pieces with 18" models.)
Additional glowing effect can be achieved
by fraying edges of ember material.

Figure 16 - Placement of Embers

Place Glowing Embers
on Burner Ports