Operation – Design Dynamics PFS VF-18P-MHD User Manual

Page 18

Advertising
background image

www.fmiproducts.com

116986-01H

18

Lighting with Piezo Ignitor
1. Disconnect ignitor cable from receiver and

connect to Piezo Ignitor Tab (see Figure
19 and Wiring Diagram on page 24).

2. STOP! Read safety information on

page 15,

3. Make sure equipment shutoff valve is fully

open.

4. Turn motor knob clockwise

to the

OFF position.

5. Wait (5) minutes to clear any gas and

then smell for gas around heater and
near floor. If you smell gas, STOP! follow
"B" on page 15.

6. ON/OFF switch in "—" ON position.
7. MAN knob on valve is in MAN position

(see Figure 19), When in MAN position
you can see a metallic core.

8. Push and hold down metal core fully with

a pen while the pilot gas flows.

9. Press and release piezo ignitor button until

pilot lights.

10. Continue holding down metal core for

about 10 seconds and then release the
metal core. Pilot should stay lit. If not,
repeat steps 1 through 4.

11. Turn MAN Knob to ON position - main gas

flows.

12. Turn motor knob to adjust flame. Knob

has a slipping clutch that allows manual
flame height adjustment.

TO TURN GAS OFF

TO APPLIANCE

Press OFF button on remote control to switch
off main gas and pilot gas or manually turn
Motor knob clockwise

to the "O" OFF

position.

oPeRaTIoN

Continued

MANUAL LIGHTING

PROCEDURE

WARNING: Manual lighting

must be performed by a qualified

service person.

The system has a "MANUAL OVERRIDE"
feature that allows you to light with a match.

Lighting with a Match
1. STOP! Read the safety information on

page 15 .

2. Make sure equipment shutoff valve is fully

open.

3. Turn motor knob clockwise to

to

OFF position.

4. Wait (5) minutes to clear any gas and then

smell for gas around heater and near floor.
If you smell gas, STOP! follow "B" on page
15. If you do not smell gas, go to the next
step.

5. Make sure ON/OFF switch is in "–" (ON)

position.

6. MAN-knob (valve) in MAN position, a

metallic core is visible (see Figure 19).

7. Push and hold down metal core fully by

using a non-sharp object such as a pen.
This lets the pilot gas flow.

8. Light pilot burner with a match, (see

Figure 20).

9. Continue holding down metal core for

about 10 seconds. Pilot should stay lit
after releasing metal core. If not, repeat
step 1 thru 4.

10. Turn MAN knob to the ON position. This

lets main gas flow.

Figure 19 - Control Valve

Piezo
Ignitor
Tab

Metallic
Core for
Manual
Ignition

Piezo Ignitor

ON/OFF Switch

Microswitch

MAN Knob
in Manual
Position

Motor
Knob
in ON
Position

Figure 20 - Pilot

Pilot Burner

Thermocouple

11. Turn motor knob to adjust flame. Knob has

a slipping clutch that allows manual flame
height adjustment as well as adjustment
to pilot gas.

Advertising