CONNECTING TO GAS SUPPLY

WARNING: This appliance

requires a 1/2" NPT (National

Pipe Thread) inlet connection

to the shutoff valve.

WARNING: A qualified service

person must connect heater to gas

supply. Follow all local codes.

CAUTION: Never connect

propane/LP fireplace directly

to the propane/LP supply. This

heater requires an external regu-

lator (not supplied). Install the

external regulator between the

heater and propane/LP supply.

WARNING: Never connect

natural gas fireplace to private

(non-utility) gas wells. This

gas is commonly known as

wellhead gas.

INsTallaTIoN

Continued

Fitting

Flexible Gas Hose
(if allowed by local
codes)

Figure 10 - Attaching Flexible Gas Hose

to Regulator

Installation Items Needed
Before installing heater, make sure you have
the items listed below.
• external regulator (for propane/LP units

only, supplied by installer)

• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection *
• sediment trap
• tee joint
• pipe wrench
• approved flexible gas line with gas connec-

tor (if allowed by local codes)

* A equipment shutoff valve with 1/8" NPT
tap is an acceptable alternative to test gauge
connection. Purchase the optional equipment
shutoff valve from your dealer. See Acces-
sories
, page 25.
For propane/LP units, the installer must
supply an external regulator. The external
regulator will reduce incoming gas pressure.
You must reduce incoming gas pressure to
between 11" and 14" of water. If you do not re-
duce incoming gas pressure, heater regulator
damage could occur. Install external regulator
with the vent pointing down as shown in Figure
11. Pointing the vent down protects it from
freezing rain or sleet.

CAUTION: Use only new,

black iron or steel pipe. Inter-

nally-tinned copper tubing may

be used in certain areas. Check

your local codes. Use pipe of

1/2" diameter or greater to allow

proper gas volume to heater. If

pipe is too small, undue loss of

volume will occur.

Figure 11 - External Regulator With Vent

Pointing Down

Propane/LP
Supply Tank

External
Regulator
with Vent
Pointing
Down

Installation Items Needed
• control cover kit (provided with heater)
• approved flexible gas hose (if allowed by

local codes)

• sealant (resistant to propane/LP gas, not

provided)

1. Apply pipe joint sealant lightly to male

threads of gas fitting (not provided).
Connect approved flexible gas hose to
inlet side of gas control (see Figure 10).
IMPORTANT: Hold gas fitting with wrench
when connecting flexible gas hose.

2. Position heater assembly in fireplace.
3. Connect to gas supply. See Connecting

to Gas Supply.