oPeRaTIoN

Continued

Shut Off Procedure
To save battery power, press

to turn main

gas to pilot gas. Press the OFF button to
shut off the device including pilot flame. The
device can be shut off with ON/OFF switch,
thus disabling remote hand set.

Setting Display ( °C/24h and °F /12h)
Press and hold OFF and

until display

changes from °F (and 12 hour clock) to °C
(and 24 hour clock) or vice versa.

Setting The Time
• After connecting battery or by simultane-

ously pressing

and

the display will

start to flash. You are in the set mode.

• From SET mode press

to set the hour

and

to set the minute.

• Wait or press OFF to return to manual

mode.

Battery Replacement
Remote handset battery needs to be changed
when LED is dim. Battery life expectancy is
2 to 3 years. Replacement is recommended
at the beginning of heating season. Battery
needs to be changed when acoustic error
message appears during ignition (see Identify-
ing Error Signals from Receiver,
page 24).

Changing Mode of Operation
• Press the SET button quickly to change the

mode of operation in the following order:

MAN,

TEMP, TEMP, TIMER.

• Manual flame height adjustment (MAN ap-

pears on display): Press

to turn on the

fire (main burner) or to increase flame height.
Press

to decrease flame or to go down

to pilot only. The receiver acknowledges the
transmission with an acoustic signal.

• The day time temperature mode ( TEMP

appears on display): The sensor in the
transmitter measures room temperature.

The controller compares the room tem-
perature with set temperature and sends
a signal to the receiver to turn gas valve
motor up or down, to adjust flame height
accordingly.

• The nighttime setback temperature (

TEMP appears on display): The sensor in
the transmitter measures the temperature
and adjusts it according to the nighttime
setback temperature. There is a bigger
temperature differential during this cycle.

• Timer: The timer mode (TIMER) operates

much like the temperature mode above.
The timer setting allows you to set specific
times for on and off. (There are 2 burner
on and 2 burner off cycles every 24 hours.)
If the reading for the nighttime temp. is
"– – –", the motor will turn off the valve to
standby pilot position and wait for the next
burner on cycle. This display shows the
setting temperature every 30 seconds.

Setting Temperature
• Select the desired mode of operation

(day or night) by pressing the SET button
briefly.

• Hold SET button until display flashes.
• Set temperature with the

or

(40°F is

the minimum temperature).

• Wait or press OFF to go to temperature

control mode.

• If temperature control in moon times

should be off (lower battery consumption),
decrease night temperature until "– – –"
appears on display.

Set Timer
• Switch to timer mode by pressing the SET

button briefly.

• Press the SET button until P1

flashes.

• Set hours with

and minutes with

.

• Press SET briefly for the next burner cycle

time.

• If all 4 times are set, pressing the OFF but-

ton or waiting will complete programming.

Shutting Off Heater
Press OFF button on remote control to switch
off main gas and pilot gas.

Shutting Off Burner Only (pilot stays lit)
Press

to decrease the flame height and

shut off main burner.

SET

OFF

STAND

BY

Figure 18 - Control Panel for Hand-Held

Remote

Advertising